class="resources"
Applies an Exact Blackman window to the input signal X. Details Example

![]() |
X is the input signal. |
![]() |
Exact Blackman{X} is the input signal with the Exact Blackman window applied. |
![]() |
error returns any error or warning from the VI. You can wire error to the Error Cluster From Error Code VI to convert the error code or warning into an error cluster. |
If y represents the output sequence Exact Blackman{X}, the Exact Blackman Window VI obtains the elements of y from
yi = xi[a0 a1cos(w) + a2cos(2w)]
for i = 0, 1, 2, , n 1
,
where n is the number of elements in X,
a0 = 7938/18608,
a1 = 9240/18608, and
a2 = 1430/18608.
Refer to the Window Comparison VI in the labview\examples\analysis\windxmpl.llb directory for an example of using the Exact Blackman Window VI.