class="resources" Kaiser-Bessel Window (Not in Base Package) - LabVIEW 7.1 Help - Support - National Instruments
Company Events Academic NI Developer Zone Support Solutions Products & Services Contact NI MyNI

Kaiser-Bessel Window (Not in Base Package)

Applies a Kaiser-Bessel window to the input sequence X(t). Details  Example

X(t) is the input signal.
beta is proportional to the side lobe attenuation. That is, the larger beta is, the greater the side lobe attenuation. The default is 0.0.
Kaiser-Bessel{X(t)} is the input signal with the Kaiser-Bessel window applied.
error returns any error or warning from the VI. You can wire error to the Error Cluster From Error Code VI to convert the error code or warning into an error cluster.

Kaiser-Bessel Window Details

If y represents the output sequence Kaiser-Bessel{X(t)}, the Kaiser-Bessel Window VI obtains the elements of y from

for i = 0, 1, 2, …, n – 1

where n is the number of elements in X(t), and Io(·) is the zero-order modified Bessel function.

Example

Refer to the Window Comparison VI in the labview\examples\analysis\windxmpl.llb directory for an example of using the Kaiser-Bessel Window VI.

 


Resources


 

Your Feedback! poor Poor  |  Excellent excellent   Yes No
 Document Quality? 
 Answered Your Question? 
Add Comments 1 2 3 4 5 submit