Counter Input >> Position >> Linear Encoder >> Distance Per Pulse

NI-DAQmx C Reference Help

Edition Date: January 2019

Part Number: 370471AM-01

»View Product Info
Download Help (Windows Only)
Data Type: float64
Description: Specifies the distance to measure for each pulse the encoder generates on signal A or signal B. This value is in the units you specify with Units.


You can get/set/reset this property using:

  DAQmxGetCILinEncoderDistPerPulse

  DAQmxSetCILinEncoderDistPerPulse

  DAQmxResetCILinEncoderDistPerPulse