Description: (Deprecated) Specifies the type of trigger to use to advance to the next entry in a switch scan list.


Valid values

DAQmx_Val_DigEdge 10150 Advance to the next entry in a scan list on the rising or falling edge of a digital signal.
DAQmx_Val_Software 10292 Advance to the next entry in a scan list when you call DAQmxSendSoftwareTrigger().
DAQmx_Val_None 10230 Advance through all entries in the scan list as fast as possible.



You can get/set/reset this property using:

  DAQmxGetAdvTrigType

  DAQmxSetAdvTrigType

  DAQmxResetAdvTrigType