Data Type: int32
Description: Specifies whether the task pauses above or below the threshold you specify with Level.


Valid values

DAQmx_Val_AboveLvl 10093 Pause the measurement or generation while the signal is above the threshold.
DAQmx_Val_BelowLvl 10107 Pause the measurement or generation while the signal is below the threshold.



You can get/set/reset this property using:

  DAQmxGetAnlgLvlPauseTrigWhen

  DAQmxSetAnlgLvlPauseTrigWhen

  DAQmxResetAnlgLvlPauseTrigWhen

WAS THIS ARTICLE HELPFUL?