Analog Input >> General Properties >> Signal Conditioning >> Excitation >> AC Excitation >> Wire Mode

NI-DAQmx C Reference Help

Edition Date: January 2019

Part Number: 370471AM-01

»View Product Info
Download Help (Windows Only)
Data Type: int32
Description: Specifies the number of leads on the LVDT or RVDT. Some sensors require you to tie leads together to create a four- or five- wire sensor. Refer to the sensor documentation for more information.


Valid values

DAQmx_Val_4Wire 4 4-wire.
DAQmx_Val_5Wire 5 5-wire.
DAQmx_Val_6Wire 6 6-wire.



You can get/set/reset this property using:

  DAQmxGetAIACExcitWireMode

  DAQmxSetAIACExcitWireMode

  DAQmxResetAIACExcitWireMode

WAS THIS ARTICLE HELPFUL?