Counter Output >> General Properties >> Counter Timebase >> Digital Synchronization >> Enable

NI-DAQmx C Reference Help

Edition Date: January 2019

Part Number: 370471AM-01

»View Product Info
Download Help (Windows Only)
Data Type: bool32
Description: Specifies whether to synchronize recognition of transitions in the signal to the internal timebase of the device.

This property does not affect the minimum pulse width recognized by the device, but setting this property to TRUE does limit the speed at which the device recognizes transitions to less than the frequency of the internal timebase.



You can get/set/reset this property using:

  DAQmxGetCOCtrTimebaseDigSyncEnable

  DAQmxSetCOCtrTimebaseDigSyncEnable

  DAQmxResetCOCtrTimebaseDigSyncEnable

WAS THIS ARTICLE HELPFUL?

Not Helpful