niFgen Init Ext Cal VI

NI Signal Generators Help (NI-FGEN 18.1)

Edition Date: April 2018

Part Number: 370524V-01

»View Product Info
Download Help (Windows Only)
Installed With: NI-FGEN

Creates and initializes a special NI-FGEN external calibration session. The ViSession returned is an NI-FGEN session that can be used to configure the device using normal attributes and functions. However, flags have been set that allow you to program an external calibration procedure using the special calibration properties and VIs. The NI 5401/5404/5411/5431 and PXIe-5413/5423/5433 have different calibration VIs. Refer to the calibration procedure of the signal generator for more information.

niFgen Init Ext Cal

/images/reference/en-XX/help/370524V-01/civrn.gif

Resource Name specifies the instrument name, for example "PXI1Slot3" where "PXI1Slot3" is an instrument name assigned by Measurement & Automation Explorer (MAX).

Syntax:

Example # Device Type Syntax Variable
1 Traditional NI-DAQ device DAQ::1 (1 = device number)
2 NI-DAQmx device myDAQmxDevice (myDAQmxDevice = device name)
3 NI-DAQmx device DAQ::myDAQmxDevice (myDAQmxDevice = device name)
4 NI-DAQmx device DAQ::2 (2 = device name)
5 IVI logical name or IVI virtual name myLogicalName (myLogicalName = name)

For Traditional NI-DAQ devices, the syntax is DAQ::n, where n is the device number assigned by MAX, as shown in Example 1.

For NI-DAQmx devices, the syntax is just the device name specified in MAX, as shown in Example 2. Typical default names for NI-DAQmx devices in MAX are Dev1 or PXI1Slot1. You can rename an NI-DAQmx device by right-clicking on the name in MAX and entering a new name.

An alternate syntax for NI-DAQmx devices consists of DAQ::NI-DAQmx device name, as shown in Example 3. This naming convention allows for the use of an NI-DAQmx device in an application that was originally designed for a Traditional NI-DAQ device. For example, if the application expects DAQ::1, you can rename the NI-DAQmx device to 1 in MAX and pass in DAQ::1 for the resource name, as shown in Example 4.

If you use the DAQ::n syntax and an NI-DAQmx device name already exists with that same name, the NI-DAQmx device is matched first.

You can also pass in the name of an IVI logical name or an IVI virtual name configured with the IVI Configuration utility, as shown in Example 5. A logical name identifies a particular virtual instrument. A virtual name identifies a specific device and specifies the initial settings for the session.

Caution  Traditional NI-DAQ and NI-DAQmx device names are not case-sensitive. However, all IVI names, such as logical names, are case-sensitive. If you use logical names, driver session names, or virtual names in your program, you must ensure that the name you use matches the name in the IVI Configuration Store file exactly, without any variations in the case of the characters.
/images/reference/en-XX/help/370524V-01/cstr.gif

Password specifies calibration password required to open an external calibration session to the device.

/images/reference/en-XX/help/370524V-01/cerrcodeclst.gif

error in describes error conditions that occur before this node runs. This input provides standard error in functionality.

Default value: no error

/images/reference/en-XX/help/370524V-01/iivrn.gif

Instrument Handle Out passes a reference to your instrument session to the next VI.

/images/reference/en-XX/help/370524V-01/ierrcodeclst.gif

error out contains error information. This output provides standard error out functionality.