For alias-protected decimation applications, complete the following steps:

  1. Set the DDC Enabled property to True.
  2. Set the Data Processing Mode property to Real.
  3. Set the Min Sample Rate property to the desired decimated sample rate.
  4. Set the Frequency Translation Enabled property to False.