NI-DCPower (English | Japanese) |
Short Name: DC Noise Rejection
Property of niDCPower
Determines the relative weighting of samples in a measurement.
![]() |
Note This property is not supported by all devices. Refer to Supported Properties by Device for information about supported devices. |
For information about improving noise immunity for NI-DCPower devices that support DC noise rejection, refer to Measurement Noise Rejection
Default Value: Normal
Related topics:
Normal (1044) |
Normal DC noise rejection. |
Second-Order (1043) |
Second-order DC noise rejection. Refer to Configuring the Measure Unit for supported devices. |
The following table lists the characteristics of this property.
Datatype | ![]() |
Permissions | Read/Write |
High-level VIs | N/A |
Channel-based | No |
Resettable | No |