niDCPower_ConfigureCurrentLimit

NI DC Power Supplies and SMUs Help (NI-DCPower)

Edition Date: January 2018

Part Number: 370736U-01

View Product Info

DOWNLOAD (Windows Only)


NI-DCPower (English | Japanese)

ViStatus niDCPower_ConfigureCurrentLimit(ViSession vi, ViConstString channelName, ViInt32 behavior, ViReal64 limit);

Purpose

Configures the current limit for the specified channel(s). The channel must be enabled for the specified current limit to take effect. Refer to the niDCPower_ConfigureOutputEnabled function for more information about enabling the output channel.

The current limit is the current that the output should not exceed when generating the desired voltage level. The current limit setting is applicable only if the output function of the channel is set to NIDCPOWER_VAL_DC_VOLTAGE. Use niDCPower_ConfigureOutputFunction to set the output function.

Related Topics:

Compliance

Parameters

Input
Name Type Description
vi ViSession Identifies a particular instrument session. vi is obtained from the niDCPower_InitializeWithChannels function.
channelName ViConstString Specifies the output channel(s) to which this configuration value applies. Specify multiple channels by using a channel list or a channel range. A channel list is a comma (,) separated sequence of channel names (for example, 0,2 specifies channels 0 and 2). A channel range is a lower bound channel followed by a hyphen (-) or colon (:) followed by an upper bound channel (for example, 0-2 specifies channels 0, 1, and 2). In the Running state, multiple output channel configurations are performed sequentially based on the order specified in this parameter.
behavior ViInt32 Specifies how the output should behave when the current limit is reached.

Defined Values:
NIDCPOWER_VAL_CURRENT_REGULATEControls output current so that it does not exceed the current limit. Power continues to generate even if the current limit is reached.
limit ViReal64 Specifies the current limit, in amps, on the specified channel(s). The limit is specified as a positive value, but symmetric positive and negative limits are enforced simultaneously.

Valid Values:
The valid values for this parameter are defined by the current limit range that is configured using the niDCPower_ConfigureCurrentLimitRange function.

Return Value

Name Type Description
StatusViStatusReports the status of this operation. To obtain a text description of the status code, call the niDCPower_error_message function. To obtain additional information concerning the error condition, call the niDCPower_GetError function.