NI VeriStand 2018 Help
Edition Date: May 2018
Part Number: 372846M-01
»View Product Info
NI VeriStand supports NI-XNET devices, NI-DAQ devices, and NI FPGA targets.
 |
Note For the best performance, NI VeriStand recommends that NI-DAQ devices support single-point timed hardware I/O or on-demand sampling. Refer to the KnowledgeBase for a list of NI-DAQ devices that support single-point timed hardware I/O. |
The following table shows the features available with each type of hardware.
Feature |
NI-XNET Devices |
NI-DAQ Devices |
NI FPGA Targets |
Custom FPGA VIs |
– |
– |
Yes1 |
Hardware timing |
– |
Yes |
Yes |
Analog I/O |
– |
Yes |
Yes |
Digital I/O |
– |
Yes |
Yes |
Pulse Width Modulation (PWM) I/O |
– |
Yes2 |
Yes |
Auto-discovery of installed devices and I/O modules |
Yes |
Yes |
Yes |
1 Refer to FPGA Targets with Built-in Support below for a list of NI FPGA targets for which NI VeriStand provides bitfiles and FPGA configuration files.
2 The following list describes device support for this feature:
- Generating pulses—If hardware-timed single-point sample mode is enabled (default) for a counter output channel, only X Series PCI and PXI devices support generating pulses with that channel. However, if that property is disabled for a CO channel, all DAQ devices support generating pulses.
- Measuring pulses—Only X Series PCI and PXI devices support measuring pulses with counter input channels.
|
Supported Targets
NI VeriStand supports deploying a project to the following targets.
-
PXI/PCI–Any PXI controller with at least 256 MB of RAM.
-
CompactRIO/Single-Board RIO–Any CompactRIO or Single-Board RIO device with at least 128 MB of RAM.
-
Desktop PC–Any PC running Windows 7, Vista, XP Service Pack 3 or later, Server 2003 R2 (32-bit), or Server 2008 R2 (64-bit).
FPGA Targets with Built-in Support
NI VeriStand ships with bitfiles and FPGA configuration files for the following FPGA targets:
- NI cRIO-9103–The files provided for the NI cRIO-9103 are configured for the NI 9215, NI 9263, NI 9411, and NI 9474 I/O modules.
- NI PXI/PCI-7811R
- NI PXI/PCI-7813R
- NI PXI/PCI-7831R
- NI PXI/PCI-7833R
- NI PXI/PCIe-7841R
- NI PXI/PCIe-7842R
- NI PXI/PCIe-7851R
- NI PXI/PCIe-7852R
- NI PXI-7853R
- NI PXI-7854R
All bitfiles use direct memory access (DMA) to transfer data.
You can use the LabVIEW FPGA Module to create custom FPGA bitfiles for these or other FPGA targets.
Supported SCXI Modules
NI VeriStand supports adding the following SCXI DAQ modules to system definitions:
- SCXI-1100
- SCXI-1102
- SCXI-1102B
- SCXI-1102C
- SCXI-1104
- SCXI-1104C
- SCXI-1112
- SCXI-1120
- SCXI-1120D
- SCXI-1121
- SCXI-1122
- SCXI-1124
- SCXI-1125
- SCXI-1126
- SCXI-1127
- SCXI-1128
- SCXI-1140
- SCXI-1141
- SCXI-1142
- SCXI-1143
- SCXI-1160
- SCXI-1161
- SCXI-1162
- SCXI-1162HV
- SCXI-1163
- SCXI-1163R
- SCXI-1190
- SCXI-1191
- SCXI-1192
- SCXI-1520
- SCXI-1530
- SCXI-1531
- SCXI-1540
- SCXI-1581
Related Link
Adding and Configuring DAQ Devices