Save Changes (VI)

NI System Configuration API 18.0 Help

Edition Date: May 2018

Part Number: 373107N-01

»View Product Info
Download Help (Windows Only)
Installed With: NI System Configuration

Saves changes made to hardware and systems.

Use the pull-down menu to select an instance of this VI.

Save Changes (Hardware)

Writes and saves property changes on a device. Save Changes (Hardware) VI wires into the Hardware Property node where property changes are selected.

Save Changes (Hardware)

/images/reference/en-XX/help/373107N-01/crn.gif

Resource in is the resource receiving property changes.

/images/reference/en-XX/help/373107N-01/cerrcodeclst.gif

error in (no error) describes error conditions that occur before this node runs. This input provides standard error in functionality.

/images/reference/en-XX/help/373107N-01/cu32.gif

Remote Timeout specifies the time in milliseconds that this VI waits before it times out. The default amount of time that the VI waits for a response on the network before timing out is 5 minutes. In some cases, the operation may take longer to complete. This timeout is for remote systems only.

/images/reference/en-XX/help/373107N-01/irn.gif

Resource out returns basic information about the system resource.

/images/reference/en-XX/help/373107N-01/istr.gif

Detailed Result is a string containing results of any errors that may have occurred during the VI execution. This parameter also may return additional information about the results of the VI execution.

/images/reference/en-XX/help/373107N-01/ibool.gif

Changes Require Restart specifies whether the changes require a reboot to take effect. If TRUE, run the Restart VI.

/images/reference/en-XX/help/373107N-01/ierrcodeclst.gif

error out returns error information. This output provides standard error out functionality.

Save Changes (System)

Writes and saves property changes on a system. Save Changes (System) VI wires into the System Property node where property changes are selected.

Save Changes (System)

/images/reference/en-XX/help/373107N-01/cio.gif

Session in specifies the system receiving changes.

/images/reference/en-XX/help/373107N-01/cerrcodeclst.gif

error in (no error) describes error conditions that occur before this node runs. This input provides standard error in functionality.

/images/reference/en-XX/help/373107N-01/cu32.gif

Remote Timeout specifies the time in milliseconds that this VI waits before it times out. The default amount of time that the VI waits for a response on the network before timing out is 5 minutes. In some cases, the operation may take longer to complete. This timeout is for remote systems only.

/images/reference/en-XX/help/373107N-01/iio.gif

Session out returns the refnum for the system.

/images/reference/en-XX/help/373107N-01/istr.gif

Detailed Result is a string containing results of any errors that may have occurred during the VI execution. This parameter also may return additional information about the results of the VI execution.

/images/reference/en-XX/help/373107N-01/ibool.gif

Changes Require Restart specifies whether the changes require a reboot to take effect. If TRUE, run the Restart VI.

/images/reference/en-XX/help/373107N-01/ierrcodeclst.gif

error out returns error information. This output provides standard error out functionality.

WAS THIS ARTICLE HELPFUL?