Error CodeHexadecimal CodeError and Status CodeDescription
10733568010x3FFA2001 NISWITCH_WARN_PATH_REMAINSSome connections remain after disconnecting.
10733568020x3FFA2002 NISWITCH_WARN_IMPLICIT_CONNECTION_EXISTSThe channels are implicitly connected.
-10741309430xBFFA1001 NISWITCH_ERROR_TRIGGER_NOT_SOFTWAREThe trigger source is not a software trigger.
-10741268470xBFFA2001 NISWITCH_ERROR_INVALID_SWITCH_PATHInvalid path string.
-10741268460xBFFA2002NISWITCH_ERROR_INVALID_SCAN_LISTInvalid Scan List string.
-10741268450xBFFA2003 NISWITCH_ERROR_RSRC_IN_USEOne of the channels is a configuration channel that is in use or is a common multiplexer channel that is in use.
-10741268440xBFFA2004NISWITCH_ERROR_EMPTY_SCAN_LISTThe scan list string is empty.
-10741268430xBFFA2005NISWITCH_ERROR_EMPTY_SWITCH_PATHThe path string is empty.
-10741268420xBFFA2006NISWITCH_ERROR_SCAN_IN_PROGRESSThe switch module is currently in scanning mode, and the operation cannot be performed at this time.
-10741268410xBFFA2007NISWITCH_ERROR_NO_SCAN_IN_PROGRESSThe switch module is not currently in scanning mode, and the operation cannot be performed at this time.
-10741268400xBFFA2008NISWITCH_ERROR_NO_SUCH_PATHNo explicit path exists between the two channels.
-10741268390xBFFA2009NISWITCH_ERROR_IS_CONFIGURATION_CHANNELYou cannot make an explicit connection to a configuration channel.
-10741268380xBFFA200ANISWITCH_ERROR_NOT_A_CONFIGURATION_CHANNELOne of the non-terminal channels in the path is not a configuration channel.
-10741268370xBFFA200BNISWITCH_ERROR_ATTEMPT_TO_CONNECT_SOURCESYou cannot make a connection between two different sources.
-10741268360xBFFA200CNISWITCH_ERROR_EXPLICIT_CONNECTION_EXISTSAn explicit connection between the channels already exists.
-10741268350xBFFA200DNISWITCH_ERROR_LEG_MISSING_FIRST_CHANNELA leg in the path does not begin with a channel name.
-10741268340xBFFA200ENISWITCH_ERROR_LEG_MISSING_SECOND_CHANNELA leg in the path is missing the second channel.
-10741268330xBFFA200FNISWITCH_ERROR_CHANNEL_DUPLICATED_IN_LEGThe first and second channels in the leg are the same.
-10741268320xBFFA2010NISWITCH_ERROR_CHANNEL_DUPLICATED_IN_PATHA channel name is duplicated in the path string.
-10741268310xBFFA2011NISWITCH_ERROR_PATH_NOT_FOUNDNo path was found between the two channels.
-10741268300xBFFA2012NISWITCH_ERROR_DISCONTINUOUS_PATHThe first channel of a leg in the path is not the same as the second channel in the previous leg.
-10741268290xBFFA2013NISWITCH_ERROR_CANNOT_CONNECT_DIRECTLYThe path contains a leg with two channels that cannot be directly connected.
-10741268280xBFFA2014NISWITCH_ERROR_CHANNELS_ALREADY_CONNECTEDA leg in the path contains two channels that are already directly connected.
-10741268270xBFFA2015NISWITCH_ERROR_CANNOT_CONNECT_TO_ITSELFA channel cannot be connected to itself.
-10741268260xBFFA2016NISWITCH_ERROR_MAX_TIME_EXCEEDEDMaximum time exceeded before the operation completed.
-10741186550xBFFA4001NISWITCH_ERROR_SESSION_ALREADY_OPENAnother process has already opened a session to this switch module.
-10741186540xBFFA4002NISWITCH_ERROR_INVALID_RESOURCE_DESCRIPTORInvalid resource name.
-10741186530xBFFA4003NISWITCH_ERROR_SCANNING_NOT_SUPPORTEDYou have set an attribute or called a function that is only used for scanning, and this switch module does not support scanning (or this module does not support scanning in the current topology).
-10741186520xBFFA4004NISWITCH_ERROR_MUST_SPECIFY_MODULEYou have indicated that a non-cabled module should get its trigger from the rear connector, and the niSwitch software could not automatically detect which cabled module to route the trigger from. Be more specific (ie, specify Rear Connector of Module X).
-10741186510xBFFA4005NISWITCH_ERROR_MODULE_FIFO_LENGTH_EXCEEDEDThe scan list commands exceeds the size of memory on the switch module.
-10741186500xBFFA4006NISWITCH_ERROR_HW_COMMUNICATE_TMOError communicating with hardware. Internal timeout occurred waiting for hardware response.
-10741186490xBFFA4007NISWITCH_ERROR_TTL_BUS_REQUIREDExpecting trigger or scan advanced bus to be one of the TTL lines (TTL 0-TTL 7).
-10741186480xBFFA4008NISWITCH_ERROR_MODULE_IS_BBM_ONLYThis module requires scan mode to be Break Before Make.
-10741186470xBFFA4009NISWITCH_ERROR_1127_TTL1_CONFLICTTTL 1 conflict detected. SCXI 1127 modules constantly use the TTL 1 line. Use a different line, or power down the chassis and remove all 1127 modules from it.
-10741186450xBFFA400BNISWITCH_ERROR_INVALID_DRIVER_SETUP_STRINGThe driver setup string is invalid.
-10741186440xBFFA400CNISWITCH_ERROR_TOPOLOGY_NOT_SUPPORTEDNo legacy device supports the specified topology. Use a different topology, or configure the device under DAQmx and use the DAQmx resource descriptor.
-10741186430xBFFA400DNISWITCH_ERROR_INVALID_TOPOLOGYThe specified topology string is invalid.
-10741186420xBFFA400ENISWITCH_ERROR_HARDWARE_UNEXPECTEDLY_RESETThe device was unexpectedly power cycled. Close and re-open the session.
-10741186410xBFFA400FNISWITCH_ERROR_HANDSHAKING_INITIATION_CONFLICTThe values for Handshaking Initiation and Trigger Input are incompatible. An Immediate Trigger Input is not compatible with Measurement Device Initiated (or DMM Initiated) Handshaking Initiation.
-10741186390xBFFA4011NISWITCH_ERROR_DAQMX_DESCRIPTOR_LEGACY_RSC_TYPE A DAQmx resource descriptor was specified, but the driver setup string specifies a Legacy resource type.
-10741186380xBFFA4012NISWITCH_ERROR_AMBIGUOUS_MODEL_CODEModel code specified in the driver setup string is ambiguous. Multiple switches match the specified model code.
-10741186370xBFFA4013NISWITCH_ERROR_TRIGGER_INPUT_NOT_SUPPORTEDThe trigger input specified is not supported by the device.
-10741186360xBFFA4014NISWITCH_ERROR_INVALID_TERMINALBLOCK_FOR_TOPOLOGYThe configured terminal block is invalid for current topology.
-10741186350xBFFA4015NISWITCH_ERROR_CANT_INVERT_WHEN_SOURCE_EQUALS_DESTSignal cannot be inverted when the signal source equals the destination.
-10741186340xBFFA4016NISWITCH_ERROR_CONFLICTING_TRIGGER_ROUTE_EXISTS Requested trigger route cannot be made because a conflicting trigger route already exists.
-10741186330xBFFA4017NISWITCH_ERROR_INVALID_VALUE_FOR_DEVICE This device does not support the specified value for this attribute or operation.
-10741186320xBFFA4018NISWITCH_ERROR_TRIGGER_POLARITY_CONFLICTTrigger input polarity and scan advanced output polarity must be the same on this particular switch device.
-10741186290xBFFA401BNISWITCH_ERROR_RESERVATION_ERRORReservation error.
-10741186280xBFFA401CNISWITCH_ERROR_ANALOG_BUS_INVALIDAnalog bus invalid
-10741186270xBFFA401DNISWITCH_ERROR_POWER_LIMIT_EXCEEDEDPower limit exceeded for the switch carrier.
-10741186260xBFFA401ENISWITCH_ERROR_DEVICE_SELF_TEST_FAILED Device self-test failed.
-10741186250xBFFA401FNISWITCH_ERROR_CARD_DETECTED_DOES_NOT_MATCH_EXPECTED_CARD One or more cards for your NI SwitchBlock device have been inserted and or removed while your system was powered on. This can lead to unexpected behavior. Restart your system.
-10741186240xBFFA4020NISWITCH_ERROR_ANALOG_BUS_STATE_INCONSISTENTAn expansion bridge has been inserted or removed while your system is powered on. This can lead to unexpected behavior. Restart your system.
-10741186230xBFFA4021NISWITCH_ERROR_FIVE_VOLT_DETECT_FAILED The 5 V fuse on your NI SwitchBlock carrier is blown. Refer to your documentation for help with replacing the fuse.
-10741186220xBFFA4022NISWITCH_ERROR_SLOT_POWER_LIMIT_EXCEEDED Power limit exceeded for a specific slot in the switch carrier.
-10741186210xBFFA4023NISWITCH_ERROR_CANNOT_EXCEED_RELAY_DRIVE_LIMITThe number of relays attempted to be driven on this device has exceeded the relay drive limit for this device.
-10741186200xBFFA4024NISWITCH_ERROR_INVALID_CONNECTION_LISTInvalid NI-SWITCH connection list.
-10741186190xBFFA4025NISWITCH_ERROR_DISCONNECTION_PATH_NOT_SAME_AS_EXISTING_PATHDisconnection path is not the same as the existing path.
-10741186180xBFFA4026NISWITCH_ERROR_INVALID_RELAY_NAMESpecified relay name is invalid for this device.
-10741186170xBFFA4027NISWITCH_ERROR_ANALOG_BUS_SHARING_DIFFERENT_WIRE_MODESUnable to connect channels composed of different wire modes through the analog bus. Disconnect any devices of different wire modes from the analog bus before routing this device through the analog bus.