niSwitch Reset With Defaults VI

NI Switches Help

Edition Date: April 2015

Part Number: 375472H-01

»View Product Info
Download Help (Windows Only)

Resets the switch module and applies initial user-specified settings from the logical name used to initialize the session. If the session was created without a logical name, this VI is equivalent to the niSwitch Reset VI.

If error in describes an error that had occurred before calling niSwitch Reset With Defaults, this VI still attempts to reset the switch. However, if the attempt fails, this VI returns the error information that was passed in from error in.

Related Topics

niSwitch Reset With Defaults

/images/reference/en-XX/help/375472H-01/cio.gif

instrument handle identifies a particular NI-SWITCH session established with the niSwitch Initialize With Topology VI, the niSwitch Initialize With Options VI, or the niSwitch Initialize VI.

/images/reference/en-XX/help/375472H-01/cerrcodeclst.gif

error in describes error conditions that occur before this node runs. With the following exception, this input provides standard error in functionality. This node runs normally even if an error occurred previously. If an error occurred before this node runs, the node passes the error in value to error out, and no errors that occur while this node runs are recorded. If an error occurs while this node runs and no error occurred previously, the node sets its own error status in error out. The default is no error.

/images/reference/en-XX/help/375472H-01/cbool.gif

status is TRUE (X) if an error occurred before this VI ran or FALSE (checkmark) to indicate a warning or that no error occurred before this VI ran. The default is FALSE.

/images/reference/en-XX/help/375472H-01/ci32.gif

code is the error or warning code. The default is 0. If status is TRUE, code is a non-zero error code. If status is FALSE, code is 0 or a warning code.

/images/reference/en-XX/help/375472H-01/cstr.gif

source describes the origin of the error or warning and is, in most cases, the name of the VI that produced the error or warning. The default is an empty string.

/images/reference/en-XX/help/375472H-01/iio.gif

instrument handle out identifies a particular NI-SWITCH session established with the niSwitch Initialize With Topology VI, the niSwitch Initialize With Options VI, or the niSwitch Initialize VI and used for all subsequent NI-SWITCH calls.

/images/reference/en-XX/help/375472H-01/ierrcodeclst.gif

error out contains error information. This output provides standard error out functionality.

/images/reference/en-XX/help/375472H-01/ibool.gif

status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred.

/images/reference/en-XX/help/375472H-01/ii32.gif

code is the error or warning code. If status is TRUE, code is a non-zero error code. If status is FALSE, code is 0 or a warning code.

/images/reference/en-XX/help/375472H-01/istr.gif

source describes the origin of the error or warning and is, in most cases, the name of the VI that produced the error or warning.

WAS THIS ARTICLE HELPFUL?