Specifies the synchronization mode for the ModAcc measurement.

Namespace: NationalInstruments.RFmx.TdscdmaMX

Assembly: NationalInstruments.RFmx.TdscdmaMX.Fx40 (in NationalInstruments.RFmx.TdscdmaMX.Fx40.dll) Version: 19.1.0.49152 (19.1.0.49152)

Syntax

Visual Basic (Declaration)
Public Enumeration RFmxTdscdmaMXModAccSynchronizationMode

C#
public enum RFmxTdscdmaMXModAccSynchronizationMode

Members

Member nameDescription
SlotThe measurement uses the slot synchronization mode. The slot boundary in the acquired signal is detected, and the measurement is performed over the number of slots specified by the NationalInstruments.RFmx.TdscdmaMX.RFmxTdscdmaMXModAccConfiguration.SetMeasurementLength method, starting at the offset from the boundary specified by the NationalInstruments.RFmx.TdscdmaMX.RFmxTdscdmaMXModAccConfiguration.SetMeasurementOffset method.If you set the NationalInstruments.RFmx.TdscdmaMX.RFmxTdscdmaMX.SetTriggerType method to RFmxTdscdmaMXTriggerType.DigitalEdge, you should provide the trigger at the start of the slot from which the ModAcc Meas Offset method should be considered. If you set the Trigger Type method to RFmxTdscdmaMXTriggerType.IQPowerEdge, it is required that the received signal has either one traffic time slot or contiguous traffic time slots. Additionally, for this trigger type, the traffic time slot(s) in the received signal should be contiguous with the pilot time slot, if the pilot time slot is present.
SubframeThe measurement uses the subframe synchronization mode. The first subframe boundary in the acquired signal is detected, and the measurement is performed over the number of slots specified by the ModAcc Meas Length method, starting at the offset from the boundary specified by the ModAcc Meas Offset method.If you set the Trigger Type method to RFmxTdscdmaMXTriggerType.DigitalEdge, you should provide the trigger at the start of the subframe. If you set the Trigger Type method to RFmxTdscdmaMXTriggerType.IQPowerEdge, it is required that the received signal has either one traffic time slot or contiguous traffic time slots. Additionally, the traffic time slot should be contiguous with the active pilot time slot.

See Also